Very High Speed, Intelligent Load Cell Interface Card

PDF Version

Model LCIC-WIM Load Cell Interface Card with USB/RS232/RS485

Model LCIC-WIM Load Cell Interface Card with USB/RS232/RS485

Open LCIC-WIN - Block diagram

 
The LCIC-WIM was designed to fit the most demanding real time weighing and force measurement applications. On the one hand, it is a very fast load cell interface allows users to capture the data at around 18,000 samples per second while on the other hand, it equipped with powerful processor, 8 I/O, analog output and display that allows it to run embedded applications mainly those that required real-time and immediate response.

Can comes ready with embedded algorithm for those Applications:

Main Features

  • Very high speed; Internal A/D 52,000 samples per second
  • Updating the PC at streaming mode at a rate of 18,000 samples per second
  • 24 Bit A/D with ± 8 million counts for tension and compression applications
  • Powerful 32 bit / 135 MIPS DSP for high speed onboard processing. OEM applications can be embedded on the board
  • 4 opto-isolated outputs configurable as setpoints, latching alarms or user outputs
  • 4opto-isolated inputs; Input #1 has counter option
  • Analog output 0 to 2.5V,16  bit resolution
  • 8 digit LED display,  LEDS to show the board status and I/O status
  • Easily updating of firmware, free to download from our web site
  • On board temperature sensor
  • USB Interface; 2.0 Full Speed compatible
  • RS232/RS485 communications. Ideal for PLC based applications
  • Multiple boards may be connected via USB or RS485

Specifications Load Cell input

  • 5 Volt excitation for up to 10 load cells in parallel (350 Ohm)
  • Compatible with 1,2,3 mV/V strain gage load cells
  • Low noise wide bandwidth amplifier & 24 bit ADC
  • Standard  interfaces
  • USB 2.0 Full Speed compatible
  • Combined RS232/RS485

Outputs

  • 4 opto-isolated solid state relays rated at 50V, 300mA Configurable as setpoints, latching alarms or user outputs. Each with status LED.
  • Adjustable Analog output (0 - 2.5V) with 16 bit resolution.

Inputs

  • 4 opto-isolated inputs with 10-30 VDC range. Each with status LED
  • Input #2 configurable as high speed counter
  • Input #1 configurable as sample trigger (option)

Dimensions (mm)

  • Standard OEM model 160 x 100mm (1/2 Eurocard)
  • ABS cased (option)        Standard OEM model 160 x 100mm (1/2 Eurocard)
  • ABS cased (option)

Software included:

  • LCIC-WIM Calibration Wizard software is included with each board
  • Drivers and examples for programmers on how to communicate with the board
  • PC application software for easy start-up for each one of our embedded applications

Our LCIC-WIM Monitoring package utility- A vital tool for analyzing dynamic load/force applications

truck at 55kmh

Graph was taken with the Monitoring utility, showing truck axles measured at 55 km/hr

AddThis Social Bookmark Button
ims-banner
Mailing Address: P.O. BOX 6305, Haifa, Israel, 31062
Shipping Address: 34 Shimshon Str. Haifa Israel

Tel: +972 (4) 811-0877
Fax:+972 (4) 811-0875
This email address is being protected from spambots. You need JavaScript enabled to view it.